This post is dedicated to the deployment of HP Insight Control for vCenter, an addon for VMware vSphere and storage administrators that need more insight in their systems or more control using a single tool.
As you might have seen in my post Deploying VMware vSphere on HP BladeSystem best practices HP Insight Control for vCenter is of great value when you are administrating a vSphere environment running on HP blades and maybe even using HP storage series like StoreVirtual or 3PAR. All information of these systems and access to Out-of-Band utilities will be available in one place after installing the software: the vSphere (Web) Client.
This post is written using HP Insight Control for vCenter 7.2.3.
Features in this release and older releases using information from the HP.com website:
Features in this release and older releases using information from the HP.com website:
Seamless integration of features in VMware vCenter Server
- Dec 11, 2014 - Download location for latest HP SMH & Insight Agents. Versions of the System Management Homepage and the Insight Management Agents.
- Click here to access the HPE SIM for HP-UX download page. Click here to access and download the HPE System Insight Management MIB Update Kits.
- Since HP's websites are so universally awful, I have never managed to successfully locate a link for the latest versions of the System Management Homepage and the Insight Management Agents.
* RECOMMENDED * HP Insight Management Agents for Windows Server 2003/2008 x64 Editions. By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement. Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee. Since HP's websites are so universally awful, I have never managed to successfully locate a link for the latest versions of the System Management Homepage and the Insight Management Agents.
- Combine physical and virtual views: From a single pane of glass, monitor the status and configuration of HP server, networking and storage that supports your virtualized infrastructure, all of this in context of the cluster, host or virtual machine selected in VMware vCenter.
- Visually trace and monitor your infrastructure network end-to-end, from the host, all the way to the individual network modules connected within your domain, delivering comprehensive management of the network making it easy for you to review and change any HP-specific information.
- View and Monitor HP Storage: Monitor the configuration of your HP Arrays portfolio by diving into detailed tables that provides the relationship between volumes to LUN connections to your virtual machines or ESX server hosts.
Reduce planned and unplanned downtime
- Automate actions on Alerts: Receive pre-failure and failure alerts on HP server components and automate evacuation of VM’s based on events that affects your physical systems. Templates are provided and ready to be configured.
- Take control by invoking HP remote management tools, such as iLO, Onboard Administrator, Virtual Connect Manager and Systems Insight Manager, in-context of the host you have selected, directly from the vCenter console.
- Accelerate configuration of VMware host networking and Virtual Connect by viewing required host networking changes and synchronizing configuration with a single click.
- Proactively manage power: Get the most out of your existing power envelope by comprehending and proactively managing power for hosts and pools of virtual machines across hosts.
Increase capacity on demand
- Deploy ESX/ESXi hosts on bare-metal ProLiant servers directly from VMware vCenter with a simple right click on a cluster or datacenter, deploy VMware hypervisor on a bare-metal server. Once deployment is completed, your newly created hypervisor is added to the appropriate cluster.
- Provision HP storage: Add new datastore, delete or expand an existing datastore, create new VMs, or clone existing VMs.
Maintain stability and reliability
- Maintain stability by monitoring and deploying firmware on HP ProLiant ESXi hosts that have the HP software bundle installed.
- Role-base security: Assign permission to Insight Control for VCenter Single-sign on using the three role levels part of VMware vCenter server to segment the level of access and control.
Hp Insight Management Agents Download Full
Now, onto the actual installation. As preperation make sure you:
- Install the software on your test environment first to see if it would help you in your daily tasks
- Download the latest version of HP Insight Control for vCenter Server (https://h20392.www2.hp.com/portal/swdepot/displayProductInfo.do?productNumber=HPICE)
- Create a service account that has the Administrator role on your vCenter Server
- Have passwords of your HP Blade Enclosure, Virtual Connect, VMware root account and vCenter Server local admin account
Start the installation of the software you just downloaded (at moment of writing this should be Insight_Control_for_VMware_vCenter_7.2.3_Software_-_Sept_2013_Z7550-01163.exe). Follow the screens shown in the gallery below. Check out the captions for information during a particular step in the wizard.
- Is this the software you want? Click next =)
- I accept, ofcourse
- Custom means more options =)
- If you don’t have HP storage like 3PAR or StoreVirtual pick Server Only, or if you don’t want to manage your software using HP Insight Control
- I accept, again
- Change if you want to
- Depends on the environment
- Change ports if needed. I didn’t have any issues installing it using these ports on a vCenter Server
- If you are upgrading an existing installation, click yes and supply the path
- All of our vSphere administrators are also allowed to manage storage. So I picked all vSphere users.
- Fill in the FQDN of your vCenter Server and supply the service account you created earlier. Caution; if your service account name is longer then supported by the pre-windows 2000 naming, use the short name here
- A summary of your configuration
- Installation will take about 5 minutes
- Installation complete! Now onto the configuration part
After finishing the installation, the software can be used without additional configuration. But to get the most out of the software, follow the next steps.
Can you help? But i have a hardware device in device manager (i think the english word) I cant get eneything out of the hardware ids? Asus maximus ix code pci simple communications controller driver windows 7. Im from Denmark thats why my windows is danish I just installed my Asus Z270F and i love it!
- Use the Insight Control for vCenter shortcut in your start menu to configure vCenter Server
- Fill in the FQDN of your vCenter Server
- Enter the vCenter service account details you created earlier
- If you have HP SIM, enter details here. HP SIM will be used to gather even more information about your systems
- Enter the global credentials that will be used to gather information about your iLOs and Onboard Administrators of your BladeSystem Enclosures
- Done!
- Open the “Storage Administrator Portal for vCenter” in the start menu to open this screen. If you cannot login with your admin account, login with the local admin account. Click Add
- After picking a storage system (3PAR, StoreVirtual, etc) Fill in an IP address or FQDN of one of your nodes. It will automatically read your whole Management Group. If you have multiple Management Groups you need to repeat the process.
- Open vSphere (Web) client and open the HP Insight Management plugin.
- On top of the screen, open Server Password Management in the drop down menu. Add entries for your HP BladeSystem Enclosures (OA), VirtualConnect and iLOs
- After information has been supplied you can click an ESXi host in the vSphere Client and open up the HP Insight Management tab. In this tab you can access tons of information, next to easy buttons to access iLO (Out-of-Band), Onboard Administrator and VirtualConnect.
- You can also create diagrams of your ESXi host that shows all virtual networks, physical NICs, physical VLANs and switches. I have hidden most information as this could be classified.
Hp Insight Management Agents Download 2012 R2
After you are done, you have created a single pane of glass for administrating VMware vSphere, physical blades, VirtualConnect, Onboard Administrators and your HP Storage!
Related articles
- Deploying #VMware #vSphere on #HP BladeSystem best practices (snowvm.com)
Hp Insight Management Agents Download Software
Purpose
![Agents Agents](https://softwaresupport.softwaregrp.com/documents/10192/35920/detail_home.png/b815ac2f-fb59-4b04-8a72-09bed7ce7575?t=1433000831145)
Hp Insight Management Agents Download
This article gives the steps to install HP Management Tools on a Vmware ESX 4.x host.
Steps
- Download HP Management Tools for ESX
- hpmgmt-8.7.0-vmware4x.tgz
- Use Filezilla client or SCP to Copy file to the ESX Host
- Open CLI on ESX hos
- Stop all VM Guests (Power Off or Suspend)
- Uncompress install package in temporary location
- tar -zxvf hpmgmt-8.7.0-vmware4x.tgz
- Change Directory to hpmgmt870
- Run install870vib.sh
- ./install851vib.sh --install
- OR
- ./install851vib.sh --silent
- Enter SNMP RW community string
- Private
- Enter SNMP RO community string
- Public
- Enter RW Authorized Management Station (SIM Server)
- simsrv01.domain.com
- Enter RO Authorized Management Station (SIM Server)
- simsrv01.domain.com
- Skip SNMP trap destination? or maybe enter SIM server (sentinel.home.loc)
- Test modules
- To verify hpilo driver status
- service hp-ilo status
- To verify HP SNMP agents
- service hp-snmp-agents status
- To verify hpilo driver status
- HP System Management Homepage
- https://<FQDN>:2381
- Reboot the ESX Host
Configure Command
To change the default configuration values, type the following command at the root prompt:
/opt/hp/hpsmh/sbin/smhconfig
![Management Management](/uploads/1/2/6/4/126464739/165260424.jpg)
HP Install Readme
Hp Smh Download
********************************************************************************************** HP SNMP Agents README *************************************************************************************************The files contained in the HP Advanced Server Management Package for VMwareESX 4.x provides the user with multiple system management. The standard configuration would be to use the HP Systems Insight Management (HP SIM)software. For more information on HP SIM, see: http://h18013.www1.hp.com/products/servers/management/hpsim/index.htmlKNOWN ISSUES: 1. On configuring the server in Mirroring AMP mode, if a multi bit error is injected, the trap 6051 for Mirrored Memory Engaged is not getting logged in HPSIM.INSTALLATION INSTRUCTIONS:IMPORTANT:This release supports the HP Insight Manager Agents on ESX 4.x.If HP Insight Manager Agents bulletin already exists on this host, this release uninstalls the older versions of agents before installing the new Insight Manager Agents.Note that the user must always be logged on with administratorprivileges when executing any of the instructions in this document.For the agents to be installed or uninstalled, the ESX host must be in maintenancemode. To be able to transition into maintenance mode, ESX requires that the virtual machines must be in either power off or suspend state.The installation script will attempt to put the system into maintenance mode if it is not already in that mode. The installation scripts check for the existence of virtual machines and what state the virtual machine is in. If a virtual machine found to be active, the following message isposted on the screen, and the installation/uninstallation of the agents is terminated. HP Insight Manager Agent 8.7.0-xx Installer for VMware ESX Target System is VMware ESX 4.x build-xxxxxx Server: ProLiant DL380 G6 An active Virtual Machine [ VM_NAME ] has been detected on host [test_sys] The ESX host will be put into maintenance mode to be able to install/uninstall the agents. The Virtual Machines must be either Powered off or Suspended by the operator to allow the transition of the ESX host into maintenance mode. Please modify the state of the VMs to be Suspended or powered off and then retry Agents Installation/Uninstallation.Installing and configuring HP SNMP agents on ESX 4.x:INSTALLATION:Copy the install package, hpmgmt-8.7.0-vmware4x.tgz, to a local folder on an ESX 4.x system (e.g. /home).From a command window on ESX host:Navigate to the directory where the files are copied and unzip the tar file: tar -xvzf hpmgmt-8.7.0-vmware4x.tgzNavigate into the directory hpmgmt/870.Install the HP SNMP agents with following command: ./install870vibs.sh Two installation options are available.Manual Installation:To manually install the agents, use --install option.Automated (Silent) Installation:To automate the installation of the agents, make a copy of the hpmgmt.conf.example file located in the local install folder and rename the copy to hpmgmt.conf. This file contains the installation information for the hp-snmp-agents package and firewall port configurations (for ESX 4.x). Edit this file to customize for the installation environment. Please see the example file located in the local install folder for complete details on the installation settings. At a minimum, Local Read/Write community for snmp agent should be configured.When ready to install, run the script as follows: ./install870vibs.sh --silent --inputfile hpmgmt.confThis will start the installation process immediately -- no prompts for confirmation will be requested. If information is missing from the configuration file, the missing information may be prompted for during installation.To automate the configuration of the System Management Homepage, placea copy of the smhpd.xml file with the desired settings into the same directory as the configurevm870.sh script (located in /opt/hp/hp-agents-config folder).When performing a silent install, this file will be copied to the appropriate directory. It is recommended to use a file from a pre-existing installation rather than edit by hand.After successful installation, output similar to the following is displayed in the command window: -------------------------------------------------------------------------------HP Insight Manager Agent 8.7.0-xx Installer for VMware ESX Target System is VMware ESX 4.x.x build-xxxxx Server: ProLiant DL380 G6Putting system into maintenance modeESX host Maintenance Mode is SET.Installing HP Insight Manager Agents bulletin [classic-mgmt-solution-870.xx.xxxx]..OKNOTE: New snmpd.conf entries were added to the top of /etc/snmp/snmpd.confsnmpd is startedEnabling port for hpim service (2381) in the firewall..OKEnabling port for HP System Management (2301) in the firewall..OKEnabling snmpd service in the firewall..OKEnabling port [280] for adding the HP SIM Certificate in SMH..OKStopping System Management Homepage:..OKStarting HP Insight Manager agents:..OKStarting System Management Homepage:..OKStopping SNMP stack: Stopping snmpd:..OKStarting SNMP stack: Starting snmpd:..OK*********************************************************** System Management Homepage installed successfully with ** default configuration values. To change the default ** configuration values, type the following command at ** the root prompt: ** ** /opt/hp/hpsmh/sbin/smhconfig ** ***********************************************************Please read the License Agreement for this software at/opt/hp/hp-health/hp-health.licenseBy not removing this package, you are accepting the termsof the 'License for HP Value Added Software'.HP Insight Manager agents have been configured successfully! HP SNMP agents are installed and configured Reboot the system to make the changes effective.ESX host Maintenance Mode is UNSET.ESX host Maintenance mode is reset to normal.-------------------------------------------------------------------------------After above successful configuration message is displayed, reboot the ESX host with the reboot command.The results of the VIB installation can be found in the vib_bulletin_update.log file located in the local install folder.The output from configuring the agents can be found in the file, 'hpmgmtlog' , located at /opt/hp/hp-agents-config folder.VALIDATING INSTALLATION: To validate the successful installation of the HP SNMP agents components package, several utilities can be run:From a command shell verify the components by running the following commands:To verify hpilo driver status, type: service hp-ilo statusTo verify HP SNMP agents, type: service hp-snmp-agents statussnmpwalk -v 1 localhost -c public enterprises | grep hp This command will list all SNMP Management Information Block (MIB) items associated with 'hp'. These are the HP management items.NOTE: The entry 'rocommunity public 127.0.0.1' must be in snmpd.conf for this command to display data.https://fully.qualified.name.com:2381 Point the web browser to the fully qualified name of this server (or the IP address) and port 2381. Note that 'https://' prefix and port ':2381' must be used or this will not work. This will allow login to the System Management Homepage and to view the status of the machine. The System Management Homepage uses OS accounts for authentication. Verify that the Management Processor section is seen on the homepage Click on the Integrated Lights-Out selection in the Management Processor section to get detailed 'Management Processor Integrated Lights-Out ' information.REMOVAL INSTRUCTIONS:Uninstalling HP SNMP agents:From a command window on the ESX host Navigate to the original install folder (e.g. /home/hpmgmt/870).From the original install folder, uninstall HP SNMP agents with following command: ./install870vibs.sh --uninstallThis will remove all instances of the HP Advanced Management Software except the SNMP stack.The firewall ports for the `hpim' service, port 280 and port 2301, will be disabled during uninstall of the agents. A warning is displayed because the `snmpd` service remains enabled in the firewall. If no other program is using the `snmpd` service behind the firewall, then the `snmpd` service can be disabled in the firewall by using the command 'esxcfg-firewall --disableservice snmpd'.After successful uninstallation, output similar to the following is displayed in the command window: -------------------------------------------------------------------------------HP Insight Manager Agent 8.7.0-xx Installer for VMware ESX Target System is VMware ESX 4.x.x
build-xxxxxx Server: ProLiant DL380 G6This script will now attempt to set ESX Host in Maintenance Modefor IM agents uninstall.Do you wish to continue? (y/n) yPutting system into maintenance modeESX host Maintenance Mode is SET.Stopping HP Insight Manager agents: Stopping hp-snmp-agents: [ OK ] Stopping hp-health: [ OK ]Stopping System Management Homepage: [ OK ]Stopping SNMP stack: Stopping snmpd: [ OK ]Disabling port for hpim service (2381) in the firewall [ OK ]Disabling port for HP System Insight Manager (2301) in the firewall [ OK ]Disabling port for the SIM Certificate in SHM [280] in the firewall [ OK ]WARNING: snmpd service has been enabled in the firewall.Disable this service using the command 'esxcfg-firewall --disableservice snmpd'if no other program is using itHP Insight Manager agents have been unconfigured successfully!Uninstalling HP Insight Manager Agents bulletin [hp-classic-mgmt-solution-870.xx.xxxx] ....OK HP SNMP agents are uninstalled Reboot the system to make the changes effective.ESX host Maintenance Mode is UNSET.ESX host Maintenance mode is reset to normal.-------------------------------------------------------------------------------SNMPD Operations using System Management Homepage - SNMP Configuration PageTo be able to perform the operations of start, stop, and reset of the snpmd daemon from the SNMP Configuration Page, the user must comment out the line'Defaults requiretty' in the file /etc/sudoers. Please see man sudoers for details about the 'requiretty' flag.AGENT CONFIGURATION:For the storage agents to display the correct information for the QLogic and Emulex HBAs, the libraries corresponding to the QLogic and Emulex driver versions have to be installed on the ESX Service Console.Please ensure that you run through these instructions ONLY if you do not see a link for either the HBA or the target drives in the System Management Homepage.The following steps guide you through the installation for the corresponding libraries: 1. Find the HBA driver version number. (See Additional notes below) 2. Download the libraries for the driver loaded in the vmkernel from the following links: (see additional notes below to determine which driver has been loaded in the vmkernel) Link for Emulex libraries: http://www.emulex.com/vmware/support/index.jsp Link for QLogic libraries: http://support.qlogic.com/support/oem_product_detail_vmware.asp 3. Stop the 'hpsmhd' and 'hp-snmp-agents' agents by issuing the commands from the service console, 'service hpsmhd stop' and 'service hp-snmp-agents stop' NOTE: you must be logged in as a user having administrative privileges. 4. Install the libraries which were downloaded in step 2 using the install script present in those packages. 5. First start the 'hpsmhd' service using the command 'service hpsmhd start'. 6. Then, start the 'hp-snmp-agents' service using the command 'service hp-snmp-agents start'. Additional notes: To find the version number of the HBA driver that is being using in the ESX system, the information can be found in /proc/vmware/version. Here is an example of QLogic and Emulex entries in the version file: QLogic: qla2300_707 build 96281: 7.07.04.01.3vmw Emulex: lpfcdd_732 build 96281: 7.3.2_vmw10ACKNOWLEDGEMENTS:This package contains additional 3rd-party software. By installing thissoftware you agree to the licensing terms for use of this software set forthin the LICENSE file.Copyright (c) 2010 Hewlett-Packard Development Company, L.P.
Hp Insight Management Agents Download Windows 7
Retrieved from 'https://www.bonusbits.com/index.php?title=HowTo:Install_HP_Management_Tools_on_Vmware_ESX_Host&oldid=675'